A detail section of a balcony door threshold showing waterproof membrane turned up behind the frame

Waterproofing that works on paper and fails on site usually fails at the same few places: laps, upstands and penetrations.

Water finds every gap. Waterproofing details are where the design team shows how the building keeps it out, at basements, roofs, terraces, balconies and wet rooms. Clear details reduce the risk of leaks, which are among the most common and costly building defects.

Principles

  • Continuity: the waterproofing layer must be unbroken, or deliberately lapped and sealed at joints
  • Upstands: membranes must turn up high enough at walls, doors and penetrations
  • Falls: water should drain away from vulnerable points
  • Protection: membranes need protection from damage during and after construction
  • Compatibility: materials that meet must be compatible with each other

Basements

Below-ground waterproofing depends on the groundwater conditions and the intended use of the space. In the UK, BS 8102 sets out principles for protecting below-ground structures, including types of waterproofing protection. Specialist waterproofing designers are often involved. Details should show membranes or systems, joints, penetrations and how the system ties into above-ground waterproofing.

Illustrative wall build-up from outside to inside: cladding, ventilated cavity, breather membrane, insulation, structure, vapour control layer and internal liningCladding or rainscreenVentilated cavityBreather membraneInsulationStructureVapour control layerInternal liningOutsideInside
An illustrative build-up only. Layer order and need for each layer depend on the wall type, climate and local rules.

Roofs and terraces

Show the membrane at outlets, parapets, upstands, thresholds and penetrations. Terraces over occupied spaces need particular care at door thresholds, where finished floor levels and membrane upstands often conflict.

Wet rooms

Showers and wet rooms need waterproofing beneath tiles, with falls to drains and upstands at walls. Show the tanking system and how it meets the drain and door threshold.

Use manufacturer details

Waterproofing systems come with manufacturer details and installation requirements. Base project details on them, and make sure the specified product matches the detail. Avoid mixing systems from different manufacturers at junctions unless they're confirmed compatible.

Draw the junctions

Most leaks happen at junctions: wall to floor, roof to wall, window to wall, membrane to drain. Draw every typical junction, and don't rely on the contractor to invent them.

Annotation

  • Name each layer and reference the specification
  • Show lap dimensions and upstand heights
  • Note sequencing where it matters
  • Highlight critical points

Check with a coloured pen

Trace the waterproofing line through each detail. If it stops without being sealed or lapped, water can get through.

Coordinate with other details

Waterproofing details must align with wall sections, roof plans and structural details. A membrane shown in one detail but missing from a related one creates confusion on site.

Think about testing and inspection

Some waterproofing can be tested before it's covered, such as flood testing of wet room tanking or electronic leak detection on some roof membranes. Where testing is planned, note it in the specification and allow for it in sequencing. Inspection before covering is far cheaper than finding a leak after finishes are installed.

If your team needs extra production capacity for work like this, take a look at our Architectural production services, or tell us about your project.

Related articles