Means of Egress Explained for Architects

A floor plan with dashed escape routes leading to two protected stair cores and an exit

In an emergency, people need to get out quickly and safely. Means of egress is the code's way of making sure they can.

Means of egress, often called means of escape in the UK, is how people leave a building safely in an emergency. It's one of the most important parts of any building's life safety design, and one of the first things reviewers check.

Core concepts

Most codes address the same basic questions:

  • How many people will be in each space, the occupant load
  • How many exits are needed
  • How far people must travel to reach an exit or a protected route
  • How wide exits, corridors and stairs must be
  • How routes are protected from fire and smoke
  • How exits discharge safely outside

Occupant load

Occupant load is usually calculated from floor area and a load factor based on use, or from the actual number of seats or people. In the US, IBC Chapter 10 provides occupant load factors. In England, Approved Document B provides floor space factors. The UAE Fire and Life Safety Code provides its own factors.

Number of exits

Codes require more than one exit when occupant loads or travel distances exceed limits. Exits should be remote from each other, so one fire doesn't block both.

Travel distance

Travel distance limits depend on use, whether escape is possible in one or more directions and whether the building is sprinklered. Measure travel distance along the actual route people would take, around furniture and fixed obstacles, as the code requires.

Exit width

Exit and stair widths are calculated from occupant load, using factors set by the code. Minimum widths also apply regardless of load.

Protected routes

Escape stairs and some corridors are enclosed with fire-resisting construction to protect people as they escape. Requirements for lobbies, smoke control and doors vary with building height and use.

Phased and progressive evacuation

Some buildings, such as tall residential buildings and hospitals, use strategies other than simultaneous evacuation. These need specialist fire engineering input.

Accessibility

Egress design must also consider people with disabilities, through refuges, evacuation lifts or other provisions required by the applicable code.

Show it on drawings

Coordinate

Egress affects layouts, doors, hardware, signage, lighting and fire alarm design. Coordinate early with fire engineers and MEP consultants.

Check egress in three dimensions

Plans don't show everything. Check headroom on stairs, door swings into landings and level changes along routes in sections and 3D views, because these are common causes of review comments.

Good egress design keeps people safe and is a fundamental responsibility of every design team.

US, UK and UAE at a glance
RegionWhat this guide notes
USIn the US, IBC Chapter 10 provides occupant load factors.
UKIn England, Approved Document B provides floor space factors.
UAEThe UAE Fire and Life Safety Code provides its own factors.